Study of Intra Ocular Pressure Changes after Isometric Handgrip Exercise Test in Young Adults

Authors

  • Priya CRao
  • Nataraj S.M

DOI:

https://doi.org/10.37506/ijop.v10i1.3210

Keywords:

Intraocular pressure, Handgripdynamometer

Abstract

Objective: ToStudy the effect of isometric handgrip exercise test on Intra ocular pressure in young adults
Method: Healthy young male adults in the age group of 18-22 years were selected among MBBS phase
I students of a Medical college .Sample size was 40. Heart rate and IOP were recorded at rest and after
isometric handgriptest
Results: Right eye IOP has decreased significantly from resting 16.28±1.55 to 9.30±1.79( p<0.001)
immediately after handgripexercise IOP Left eye IOP has decreased significantly from resting 16.15±1.69 to
13.04±1.19 (p<0.001)immediately after handgrip exercise IOP
Conclusion: Isometric handgripexercise lowers IOP which were significant. Hence may prove useful in
normotensive glaucomatous patients

Author Biographies

  • Priya CRao

    Associate Professor, Subbaiah Institute of Medical Sciences,Purale, Shimoga

  • Nataraj S.M

    Professor & HOD, Department of Physiology, JSS Medical College, Mysore

Downloads

Published

2022-01-04

How to Cite

Study of Intra Ocular Pressure Changes after Isometric Handgrip Exercise Test in Young Adults. (2022). International Journal of Physiology, 10(1), 16-21. https://doi.org/10.37506/ijop.v10i1.3210